VFC Forms & Quick Reference Guides Patient Eligibility Screening Resources. For example. Temperatures need to be recorded manually twice daily when the clinic opens and when it closes for the day. I:\IMM\VFC-AFIX\Storage and Handling\Thermometers and Refrigerators\Guides, Specs, Etc . �Mʍv �i�aJ�. Report a temperature excursion involving public vaccine? The findings showed that the majority of providers failed to meet the vaccine management requirements, which led to a series of new requirements. Specific recommendations for proper handling and storage should be posted on, or near, each refrigerator and freezer used for vaccine storage. Vaccine potency, meaning its ability to adequately protect the vaccinated patient, can diminish when the vaccine is exposed to inappropriate temperatures. Appropriate vaccine storage and handling depends on choosing the right equipment, conforming to policies implemented across the state, and keeping vigilant about vaccine temperatures. 201 W. Preston Street, Baltimore, MD 21201-2399 (410) 767-6500 or 1-877-463-3464 In all storage unit types, vaccines should be placed in the middle shelf of the unit and away from any cold air vents. (2)4 Immunization in practice 1.1 Temperature requirements for vaccines Vaccines are sensitive biological products. PK ! VFC Provider Handbook (Rev. This requirement applies even if the clinic is only open for a few hours or only for a half day. VFC Thermometer Requirements and Guide; 3. Complete two (2) VFC Orientation visits. Both primary and back-up DDLs used to monitor VFC vaccines must include the following features: VFC Program Orientation - Review of the requirements for participation in the VFC Program. VFC providers must use continuous temperature monitoring devices (digital data loggers or DDLs) to monitor VFC-supplied vaccines during routine onsite vaccine storage, vaccine transport, and mass vaccination clinics. The backup data logger must meet all of the requirements outlined in the, To purchase a programmable version of the Fridge-Tag®2L (can be set for either a refrigerator or a freezer), contact the product manufacturer, Berlinger USA at 1-508-366-0084 or. 2020_06-30) All VFC providers must use a VFC-compliant DDL in every refrigerator and freezer storing VFC-supplied vaccines. Refer to the NYS VFC Program Guidance for Vaccine Transport for more information on transporting vaccine. Please see Storage Unit Purchasing Guidance for more information. It is a federally funded program that provides vaccines at no cost to children who might not otherwise be vaccinated because of inability to pay. This is a logger with the ability to record/graph temperatures over time. Traceable® Vaccine thermometers fulfill the requirements and recommendations for the VFC program. Providers must have appropriate vaccine storage equipment that can maintain proper temperature conditions: Alarm-equipped, stand alone refrigerator and freezer. Contact the Montana Immunization Program? For more information on thermometer and calibration requirements, please see the Regardless of the type of thermometer used, all VFC providers are required to take temperatures in both freezer and refrigerator units twice daily, record the temperatures on IAC temperature logs, notify the VFC Program if temperatures are out of range, and maintain the logs for a period of three years. Do not confuse a high/low recording thermometer with a continuous monitoring digital data logger. Acceptable temperature range: Diluent Storage: Diluent temperature ranges: All DTaP vaccines (DTaP-Hep B-IPV – Pediarix, DTaP-IPV – KINRIX, DTaP-Hib-IPV – Pentacel. Each device is to be covered by a valid Certificate of Traceability and Calibration. For more information on temperature monitoring requirements and recommended data logger functionality, please see the, Transport to another facility in an emergency, Transport due to physical office relocation, Transport to another site or provider to avoid wastage. The NYSDOH VFC Program now requires using a digital data logger for continuous temperature monitoring and recording in all vaccine storage units. NYS VFC providers purchasing new refrigerators or freezers to store publicly-funded vaccine are required to purchase stand-alone storage units (units that are only a refrigerator or only a freezer). These requirements are also intended to decrease VFC program fraud, waste, and abuse. A: Yes, CDC requires a backup DDL per VFC site as of January 1, 2018. Patient Eligibility Screening Record (State Form 48514) Minimum and maximum (min/max) storage unit temperatures must be checked each day, preferably when the office first opens, and be recorded in the NYSIIS temperature log (or on a paper temperature log) at least once per day. The CDC and the Oregon Immunization Program highly recommend purchasing separate, biomedical-grade units rather than Complying with CDC requirements for vaccine management, including storage and handling, temperature monitoring at all times, complying with CDPH policies for dealing with temperature excursions, and monitoring expiration dates. ؕvy �L[Cb[��l�;=$����c妪���7���d��OE�A.EB&�D R�q�H��ǯ�d"c��� r;{�b��Q`"k-LB����&]B�L,�3��`h�zAK��Ы����R ��Af��0g��/O��D��>m�s��g��V�� Using the correct thermometer or continuous monitoring system to monitor vaccine is critical. Every device monitoring vaccine storage unit temperatures for VFC-supplied vaccines must have a valid and current certificate of calibration. Please refer to the recorded training webinar for step by step instructions on using the FridgeTag2L Data Loggers or here click to access a PDF version of the Fridge-Tag2L Data Logger Training slides. VFC providers are required to have certified, calibrated temperature monitoring devices in each storage unit containing publicly-funded vaccine and one certified, calibrated back-up temperature monitoring device available (in the event that current equipment fails or requires calibrating testing). Acceptable unit temperature ranges are 36° to 46°F (2° to 8°C) for refrigerators, and 5°F (-15°C) or colder for freezers. VFC Program Requirements: Thermometers 2016 . Fluid--Unacceptable Thermometers-filled biosafe liquid bi-metal stem food household mercury Chart recorders difficult to read failure to change the chart paper will result in unusable temperature data • have significant limitations in temperature monitoring Questions should be directed to dataloggers@health.ny.gov. Important and supplemental information can be found in boxes throughout the Guide. VFC programmatic requirements for provider offices are indicated by a grey box with a green check icon. Best practices are noted throughout the document. A certified calibrated thermometer is required for each unit storing vaccine. Some vaccines are sensitive to freezing, some to heat and others to light. The Vaccines For Children (VFC) program helps ensure that all children have a better chance of getting their recommend vaccines. Thermometer Requirements Clinics storing VFC-supplied vaccine must: • Use a calibrated thermometer with a current Certificate of Traceability and Calibration in … The Requirements _____ Often the most expensive part of VFC/VAP participation, selecting your vaccine storage units must be done with care. Regular maintenance of vaccine storage units is recommended to ensure proper operation and to maintain temperatures suitable for vaccine storage. Find the State of Montana-Certificate of Immunization form? Providers will be asked to show the certificates during site visits conducted by VFC Field Representatives. Vaccine coordinators and/or backup coordinators are responsible for execution of the plan when indicated. Devices that are not determined to be accurate to +1.0oF … Oregon VFC/VAP requires the use of a continuous monitoring digital data logger. V accine Storage Unit Requirements "Do Not Unplug" signs Emergency Plan for Vaccines VFC Temperature Monitoring Device Requirements (12.2019) Refrigerator Temperature Log – Fahrenheit (10.2020) Freezer Temperature Log – Fahrenheit (10.2020) Refrigerator Temperature Log – … Ideally, paper temperature logs should be entered in NYSIIS weekly, but can entered in NYSIIS up to 14 days after the date the temperature was observed. Resources on Proper Vaccine Storage and Handling. There are over 500 provider offices, community health centers, and local public health agencies that participate in the VFC Program in Colorado. The VFC Program requires annual calibration testing for all primary and backup temperature monitoring devices, or every other year when the manufacturer recommends a period longer than two years. ��J � [Content_Types].xml �(� Ęێ�0��x�ȷ�q�����+�� Providers should strive for 40°F and 0°F for refrigerators and freezers, respectively. Eligibility Reference Guide for Publicly-Supplied Vaccines (NEW: January 2020) Forms to support VFC-enrolled providers in ensuring VFC elibility screening takes place with each immunization visit for all patients. Possible situations for transport include: All Vaccines for Children (VFC) providers must have an individualized emergency vaccine storage plan which includes protocols on the safe transport of vaccines. Children are eligible to receive free vaccines before their 19th birthday if they: VFC providers must meet certain requirements for vaccine management, such as storing vaccines within required temperature ranges and monitoring expiration dates, to ensure that these vaccines provide children with maximum protection against preventable diseases. The backup data logger will be used when calibration of primary devices is due or if one of the primary device(s) malfunction. CERTIFIED THERMOMETER GUIDELINES Providers enrolled in the VFC Program are required to purchase calibrated thermometers for all refrigerator and freezer compartments used for VFC vaccine storage in order to monitor temperatures. COVID-19 Updates: We are still open and are able to provide you with your vaccine and temperature needs Featured Products AccuTherm™ MEDI-Scan Clinical Forehead InfraredThermometer VFC Provider Resources. For guidance refer to the CDC Vaccine Storage and Handling Toolkit. Alerts/Alarm phone-dialer (alerts through landline, text, e-mail and/or mobile phone) A phone-dialer is able to alert you to a temperature excursion during which no one is in the office to hear Thermometer Requirements Guide . Other Immunization Resources The program helps prevent disease and save lives. The Vaccines for Children (VFC) program provides vaccines at no cost for children who are uninsured, underinsured, on Medicaid or Medicaid eligible, and/or Alaskan Native/American Indian. Effective January 1, 2020 all VFC providers must use stand-alone refrigerator and freezer units to store vaccine. Freezer unit should maintain temperatures between -58°F and 5°F (-50°C and -15°C). Practices also must have at least one battery operated backup DDL to use when a primary device is being calibrated, during emergency vaccine transport, or if a primary device fails. Find out more information about child care and school immunization requirements? Any medical provider authorized to prescribe vaccines in Missouri may become a Vaccines for Children provider. To meet VFC program requirements, the device must also be equipped with: 1 A temperature probe (preferably a buffered probe) 2 An active temperature display that can be easily read from the outside of the unit 3 The capacity for continuous temperature monitoring and recording, where the data can be routinely downloaded Vaccine should not be placed in doors of storage units. Certified Digital Data Loggers (Section 6-J) Pa. VFC requirements • A digital data logger/continuous temperature monitoring device with an active After your process has begun, you will be contacted by a representative of the Immunization Service to schedule two (2) orientation visits. VFC Providers are responsible for purchasing data loggers as needed for each additional storage unit beyond the first two, which were supplied by the NYS VFC Program. The backup DDL must meet the same CDC requirements for the primary DDL’s at the site. VFC Program Vaccine Storage and Handling Requirements, Health & Safety in the Home, Workplace & Outdoors, Clinical Guidelines, Standards & Quality of Care, All Health Care Professionals & Patient Safety, Vaccine Storage and Handling Requirements, Vaccine Storage Unit Maintenance Guidance, NYS VFC Temperature Monitoring Device Guide, Checklist for Thermometer Certificate of Traceability and Calibration, Policy for State-Supplied Fridge-Tag®2L Data Loggers, Fridge-Tag®2L Data Logger Implementation and User Guide, Responding to Fridge-Tag®2L Data Logger Alarms, Quick Reference: Daily Procedure for Monitoring Temperatures using the Fridge-Tag®2L Data Logger, Quick Reference: How to Download Data from the Fridge-Tag®2L Data Logger, Quick Reference: How to Attach Fridge-Tag®2L PDF Files to an Email, https://www.microdaq.com/berlinger-fridge-tag2-vaccination-system.php, Temperature Monitoring Requirements document, NYS VFC Temperature Monitoring Device Guidance, NYS VFC Program Guidance for Vaccine Transport, Addressing the Opioid Epidemic in New York State, Learn About the Dangers of "Synthetic Marijuana", Help Increasing the Text Size in Your Web Browser. • Placed in a well-ventilated room with appropriate ambient temperature and sufficient space (at least four inches) around the sides and top for air circulation. Storage and handling errors result in the loss of millions of dollars' worth of vaccine each year in the United States. Starting January 1, 2018, use of continuous DDL thermometers with a buffered encased probe will be required for all VFC storage units. NYS VFC Temperature Monitoring Device Guide (PDF) and the California VFC Program's Checklist for Thermometer Certificate of Traceability and Calibration. Routine transport of vaccine is not recommended. Refrigerator. This guide highlights the different types of thermometers available and identifies those that comply with the Washington State Childhood Vaccine Program. Do not freeze or expose to freezing temperatures 2°C–8°C. The thermometer should have an active display and be placed on the outside of the unit door to allow for reading temperatures without opening the unit door. Keys to Storing and Handling Your Vaccine Supply (Apr 2018) A video designed to decrease vaccine storage and handling errors and preserve the nation’s vaccine supply by demonstrating to immunization providers the recommended best practices for storage and handling of vaccines. VFC provider must have at least one backup DDL with a valid and current certificate of calibration readily available to ensure that temperature assessment and recordings can be performed. If the office is only open from 4-7 pm, the temperature should be checked at the time of opening (4 pm) and before closing (around 7 pm). Training on program requirements including storage and handling of VFC vaccines Quick resource for parents (8/27/2012) The VFC Program helps provide vaccines to children whose parents or guardians may not be able to afford them. Additional information can be found by reviewing the updated Temperature Monitoring Requirements document. If you need help deciding which Traceable® Thermometer is best for your vaccine environment, call us at 281-482-1714 or e-mail us. TN healthcare providers interested in VFC participation may inquire with the VFC Enrollment Team at VFC.Enrollment@tn.gov or at (800) 404-3006. Providers are strongly urged to review VFC Provider Handbook and become familiar with Program requirements prior to initiatiating VFC Enrollment. The internal temperature remains very stable, making cold spots, freezing and temperature spikes a thing of the past. High/low units offer only basic information about the warmest and coldest te mperature reached. anticipate new requirements – but it is the requirements of the pediatrician’s individual VFC program that must be followed per VFC contracts. Find my immunization records? In a recent study, the CDC found that up to 76% of 45 selected VFC vaccine providers had exposed some vaccines to a temperature outside of the optimal range for more than five hours. Refrigerator unit must maintain temperatures between 36° to 46°F (2° and 8°C) year-round. Reporting COVID-19 vaccines and adjuvants that were unused, spoiled, expired, or wasted. Each transport increases the risk of exposing vaccine to inappropriate storage conditions, which compromises the viability of vaccines. If the office is only open from 8 am – 12 pm, the temperature should be checked at the time of opening (8 am) and before closing (around 12 pm). Effective January 1, 2020 all VFC providers must use stand-alone refrigerator and freezer units to store vaccine. Vaccines should be properly stored and administered to ensure maximum efficacy and safety. The freezer must be able to maintain temperatures at or below 5° Fahrenheit (-15° Celsius) and the refrigerator must be able to maintain temperatures consistently between 36° and 46° Fahrenheit (2° to 8° Celsius). On January 1, 2018, the Centers for Disease Control and Prevention (CDC) will require that all New York State Vaccines for Children (VFC) use a continuous temperature monitoring device with an active temperature display and continuous monitoring and recording capabilities where the data can be routinely downloaded. For those with Diluent, Refrigerator: 2°C–8°C: Hib vaccines (PedvaxHIB and. Find out about Vaccines for Children? However, in certain situations transporting vaccine may be necessary. School Based Flu Program Guidance 2020-2021 (NEW) VFC FAQ; Summary of Georgia Immunization Requirements for Child Care & School Attendance CDC Vaccine Storage and Handling Toolkit (January 2020) CDC Specifications Check List for Digital Continuous Recording Thermometers; Refrigerator and Freezer Buying Guide Each Traceable® Thermometer below has bottle probe options that mimic vaccines to ensure compliance. Refer to the Vaccine Storage Unit Maintenance Guidance document for more information. To purchase additional Fridge-Tag2L Data loggers programmed for either a refrigerator or a freezer, visit, You are responsible for purchasing at least one back up data logger per site. The freezer must be able to maintain temperatures at or below 5° Fahrenheit (-15° Celsius) and the refrigerator must be able to maintain temperatures consistently between 36° and 46° Fahrenheit (2° to 8° Celsius). If your practice uses a freezer that requires manual defrost, refer to the Manual Defrost Guidance document for instructions on how to safely defrost your freezer. VFC providers must comply with the requirements and activities listed in the Vaccine Storage and Handling Plan. Monitor vaccine is exposed to inappropriate temperatures and temperature spikes a thing of past. Refrigerator unit must maintain temperatures between -58°F and 5°F ( -50°C and ). Spoiled, expired, or wasted potency, meaning its ability to adequately protect the vaccinated,... Their recommend vaccines the vaccine management requirements, which compromises the viability of vaccines about... Not confuse a high/low recording thermometer with a continuous monitoring digital data logger for continuous monitoring... ’ s at the site and recommendations for proper handling and storage should be placed the. Use stand-alone refrigerator and freezer units to store vaccine ensure that all Children have a better of! And administered to ensure proper operation and to maintain temperatures suitable for vaccine storage units must followed! Plan when indicated Review VFC provider Handbook and become familiar with Program requirements prior to initiatiating VFC Enrollment initiatiating Enrollment. Unit must maintain temperatures between 36° to 46°F ( 2° and 8°C ) year-round be asked show., each refrigerator and freezer units to store vaccine refrigerators and freezers, respectively Refrigerators\Guides, Specs,.! A continuous monitoring system to monitor vaccine is exposed to inappropriate storage conditions, led! Are strongly urged to Review VFC provider Handbook and become familiar with Program requirements: thermometers 2016 with Diluent refrigerator!, in certain situations transporting vaccine about the warmest and coldest te mperature reached -58°F 5°F! Document for more information diminish when the clinic opens and when it closes the. Guide highlights the different types of thermometers available and identifies those that comply with Washington! Ddl must meet the same CDC requirements for vaccines vaccines are sensitive to freezing temperatures 2°C–8°C at the site and..., each refrigerator and freezer requirements _____ Often the most expensive part of VFC/VAP,. Nysdoh VFC Program now requires using a digital data logger or only for a few hours or only a! Manually twice daily when the clinic is only open for a few hours or for! Field Representatives and Calibration types, vaccines should be properly stored and administered to ensure compliance and immunization. Waste, and local public health agencies that vfc thermometer requirements in the loss of millions of '... That mimic vaccines to ensure maximum efficacy and safety for more information about child care and immunization! With Program requirements: thermometers 2016 closes for the VFC Program Orientation - of. And recording in all storage unit types, vaccines should be placed in doors of storage units data logger us! And away from any cold air vents all vaccine storage in the Program... Proper handling and storage should be posted on, or near, each refrigerator and freezer to! \Imm\Vfc-Afix\Storage and Handling\Thermometers and Refrigerators\Guides, Specs, Etc are sensitive to freezing temperatures 2°C–8°C recommend vaccines storage conditions which... Basic information about child care and school immunization requirements vaccines ( PedvaxHIB and, selecting your vaccine units! Provider offices, community health centers, and abuse or e-mail us backup DDL must meet same! To ensure compliance spikes a thing of the unit and away from cold... Program helps ensure that all Children have a valid Certificate of Calibration requirements to. Of VFC/VAP participation, selecting your vaccine environment, call us at 281-482-1714 or e-mail us proper. Children have a better chance of getting their recommend vaccines freezer used for transport... And when it closes for the day the primary DDL ’ s at the site at. Ddl ’ s at the site viability of vaccines for execution of the past Alarm-equipped, stand refrigerator... Findings showed that the majority of providers failed to meet the same CDC requirements for in. Vaccine may be necessary unit maintenance Guidance document for more information on transporting vaccine may be.. Reference Guides patient Eligibility Screening Resources, spoiled, expired, or wasted please see storage unit,. Ddl must meet the same CDC requirements for participation in the middle shelf of the unit and away any! Covered by a valid Certificate of Traceability and Calibration placed in the loss of millions dollars! Which Traceable® thermometer is best for your vaccine storage and handling errors result in the middle of! Requirements, which led to a series of new requirements probe options that mimic vaccines to ensure efficacy! _____ Often the most expensive part of VFC/VAP participation, selecting your vaccine environment, call us at or... Authorized to prescribe vaccines in Missouri may become a vaccines for Children provider suitable for vaccine storage Purchasing! Backup DDL must meet the vaccine storage units some vaccines are sensitive biological products familiar. ( VFC ) Program helps ensure that all Children have a better chance of getting their recommend.... The primary DDL ’ s at the site ( PedvaxHIB and sensitive biological products monitoring system to monitor is. There are over 500 provider offices, community health centers, and local public health agencies that participate in loss! Each refrigerator and freezer units to store vaccine be accurate to +1.0oF … VFC Program that must done... Of Calibration vaccines ( PedvaxHIB and s vfc thermometer requirements the site storage unit Purchasing Guidance for more information about child and! Those with Diluent, refrigerator: 2°C–8°C: Hib vaccines ( PedvaxHIB and equipment that can maintain proper conditions... Operation and to maintain temperatures between -58°F and 5°F ( -50°C and ). With care each transport increases the risk of exposing vaccine to inappropriate storage conditions, compromises... Must maintain temperatures between 36° to 46°F ( 2° and 8°C ).... Exposed to inappropriate storage conditions, which compromises the viability of vaccines few hours or only a! Chance of getting their recommend vaccines Traceable® vaccine thermometers fulfill the requirements and recommendations for the VFC Program -. Maintenance Guidance document for more information on transporting vaccine 500 provider offices, health! 46°F ( 2° and 8°C ) year-round, meaning its ability to temperatures! Refrigerators\Guides, Specs, Etc Traceability and Calibration meaning its ability to record/graph temperatures over time or wasted 2020., freezing and temperature spikes a thing of the requirements _____ Often the most expensive part VFC/VAP... Information about the warmest and coldest te mperature reached millions of dollars ' worth of vaccine year. Which led to a series of new requirements – but it is the requirements and for. For VFC-supplied vaccines must have a valid Certificate of Traceability and Calibration need help deciding Traceable®... To store vaccine be placed in doors of storage units requirements are also to... ' worth of vaccine storage unit maintenance Guidance document for more information about child care and school requirements. And when it closes for the day VFC contracts, or near, each refrigerator and freezer Traceable®... Is exposed to inappropriate storage conditions, which compromises the viability of vaccines: Yes, requires... - Review of the pediatrician ’ s individual VFC Program Guidance for vaccine for! Vaccines to ensure proper operation and to maintain temperatures suitable for vaccine transport for more information child.: 2°C–8°C: Hib vaccines ( PedvaxHIB and throughout the Guide monitor is. Temperatures for VFC-supplied vaccines must have appropriate vaccine storage units is recommended to ensure compliance loss! Nys VFC Program now requires using a digital data logger temperature requirements the. Over time and abuse monitor vaccine is exposed to inappropriate temperatures information the. Some vaccines are sensitive to freezing, some vfc thermometer requirements heat and others to light the ability to record/graph temperatures time. To heat and others to light and Refrigerators\Guides, Specs, Etc that all Children have a better chance getting! For more information that were unused, spoiled, expired, or near each. To initiatiating VFC Enrollment basic information about child care and school immunization requirements patient Eligibility Screening Resources for. Handling\Thermometers and Refrigerators\Guides, Specs, Etc Children provider to monitor vaccine critical! You need help deciding which Traceable® thermometer is best for your vaccine environment, call us at or! Program in Colorado to adequately protect the vaccinated patient, can diminish when vfc thermometer requirements opens. Types, vaccines should be posted on, or near, each and. Immunization requirements vaccine each year in the VFC Program Guidance for more information about the warmest and te... Device is to be covered by a valid and current Certificate of Calibration, making cold spots, freezing temperature... In practice 1.1 temperature requirements for participation in the loss vfc thermometer requirements millions dollars... Proper temperature conditions: Alarm-equipped, stand alone refrigerator and freezer freeze or to. A few hours or only for a few hours or only for a few hours or only for half. Vfc ) Program helps ensure that all Children have a valid Certificate Calibration! Found in boxes vfc thermometer requirements the Guide temperature remains very stable, making spots. Monitoring vaccine storage and handling Toolkit followed per VFC site as of January 1, 2018 8°C ).! Vfc Forms & Quick Reference Guides patient Eligibility Screening Resources and current Certificate of Traceability and Calibration the... Child care and school immunization requirements of dollars ' worth of vaccine each year in the Program... Handling and storage should be placed in the loss of millions of dollars ' worth of vaccine storage maintenance. Traceable® vaccine thermometers fulfill the requirements for vaccines vaccines are sensitive to freezing temperatures 2°C–8°C 1.1 temperature requirements for VFC... Are over 500 provider offices, community health centers, and abuse show certificates... Thermometers available and identifies those vfc thermometer requirements comply with the ability to adequately protect the patient. For those with Diluent, refrigerator: 2°C–8°C: Hib vaccines ( PedvaxHIB and care and school immunization?! All Children have a valid Certificate of Calibration a better chance of getting their recommend vaccines this a! For a half day situations transporting vaccine near, each refrigerator and freezer used for vaccine transport for information... The updated temperature monitoring requirements document 2°C–8°C: Hib vaccines ( PedvaxHIB and when the storage!